<load>

The element <load> contains diagrams of internal forces in the certain combination. More elements <load> have to be specified if more load combinations should be considered. This element supports following attributes:

title

  • The name, obligatory

secondOrder

  • The setting which defines whether the forces were calculated using second order theory. Available values: "true" (inner forces according to II. order), "false" (inner forces according to I. order theory). Optional, default value is "false".

combinationKind

  • The type of combination, available values: "basic", "characteristic", "frequent", "quasipermanent'"

QPCoef

  • The load duration factor, permitted range is <0,1>. Default value is 1.0

Diagrams of inner forces are defined using elements <force>. These elements contain the values of forces and moments in individual points along the member length. The element supports following attributes:

x

  • The position measured from the beginning of the member, obligatory.

N

  • The value of axial force

Vy

  • The value of shear force in the direction of the axis y

Vz

  • The value of shear force in the direction of the axis z

My

  • The value of bending moment about the axis y

Mz

  • The value of bending moment about the axis z

T

  • The value of torsional moment

The intermediate values are calculated using rules given in the software (linear interpolation). Value defined in the format like "1230;1350" refer to different value of the force on the left and on the right.

The load with specified diagrams of inner forces