GEO5 软件

在线帮助

Tree
Settings
Program:
Language:

Correction Factors for Driven Piles

The correction factors for base ηb and shaft ηs may be calculated or input for driven piles in the "Geometry" frame.

Pile type

ηb [-]

ηs [-]

Reinforced concrete and prestressed concrete

1,00

1,00

Steel tube - open

(0,30 m ≤ Db ≤ 1,60 m)

0,95.e-1,2Db

1,1.e-0,63Db

Steel tube - closed

(Db ≤ 0,80 m)

0,80

0,60

where:

Db

-

equivalent pile base diameter [m]

Literature:

German Geotechnical Society: Recommendations on Piling (EA-Pfähle). Berlin: Ernst & Sohn, 2012.

Try GEO5 software for free.